Honeywell Vista 15/20 User Manual
Honeywell Vista 50 User Manual
Honeywell Vista 128 User Manual


Business/Custom Residential

False alarm reducing features, security enhancements and end user appeal make the economical VISTA-15 the industry’s most sophisticated, versatile control. With both hardwire and wireless expansion and features like Night Arming and Cancel Verification, the VISTA-15 can meet even the most demanding requirements.

Superior Flexibility

VISTA-15 has the installation flexibility & expandability to be used in simple configurations, complex installs and everything in between.

* Six hardwired zones
* Expands to 32 total zones (up to 26 wireless and/or 14 hardwired zones)
* 16 user codes
* 48 event log with date/time stamp
* Two-wire or four-wire smoke detectors
* Fast and easy E2 programming mode

Security & False Alarm Reducing Enhancements

VISTA-15 has incorporated SIA false alarm reducing requirements with the latest technology.

* Exit delay reset
* Alarm cancel verification
* Unvacated “Auto-Stay”
* Cross zoning/alarm verification
* Short vs. open detection & reporting
* Telephone-line monitor
* Arming level increase

Valuable End User System Features

VISTA-15 offers your customers a choice of system features that add value to any install.

* Easy-to-use single button operation
* Arm Away * Arm Stay
* Arm Night * Page
* Quick exit
* Quick arm
* X-10 control & 4 relays supported for home management
* Enhanced paging capabilities
* 24-hour monitoring zone
* Compatible keypad family

Wide Selection of Easy to Use End User Interface Devices

With superior wireless remote control, phone operation and choice of keypads, VISTA-15 can be easily operated to fit your customers needs.

* Wireless remote control
– 5804 - Four button, fully programmable key
– 5804BD - Four button, fully programmable key with status feedback for added security
– 5827BD - Wireless keypad with status feedback
* Phone Control
– 4285 - Turns any touch-tone phone into a voice response keypad

 

The high capacity, feature-rich VISTA-20P lets you deliver more value to your customers on each and every sale with up to 48 zones of protection, Internet uploading/downloading, graphic keypad support and dual partitions. VISTA-20P gives you the ability to send alarm signals and upload/download via an Internet Protocol (IP), improving the speed at which information can be delivered to and from the control panel. In addition, the VISTA-20P, used with an AlarmNet Internet or digital communicator can be installed in premises without TELCO lines with no sacrifice in functionality. The panel’s installation advantages, innovative end-user benefits and robust system capacity make the value-priced VISTA-20P an ideal choice for higher end installations.

Features

* IP alarm reporting and uploading/downloading capability for Internet and Intranet use via 7845i, 7845i-ENT, 7845GSMR or 7845i-GSM
* Supports four graphic touchscreen keypads
* Wireless keys can be programmed without using zones
* Eight on-board hardwired zones standard (15 when Zone Doubling feature is used)
– 40 hardwire expansion zones
– 40 wireless expansion zones Two low current on-board trigger outputs
* 100 Event Log viewable at system keypads with time/date stamp
* 48 system user codes assignable to either partition
* Expandable to 48 total zones when used with hardwired and/or wireless expansion modules
* Two independent partitions plus a common partition
– Global Arming from any system keypad
– Goto function to view or operate one partition from the other
– Separate partition account numbers 16 output devices
*
– Relays (Model 4204 Relay Modules, or 4229 Expansion Module), and/or X-10® devices (when used with a 4300 Transformer) Four installer-configurable zone types allows the installer to create custom zone types by assigning all zone attributes
* Supports four-wire and up to 16 two-wire smokes
– Works with Sentrol CleanMe™ maintenance signal Multiple actions on output devices depending on system state
*
– Turns lights off when system arms
– Turns the same light on when system disarms
– Flashes same lights when system is in alarm Built-in phone line cut monitor with programmable delay and annunciation options
*
– Display on system keypads
– Trigger local sounders
– Trigger system bell

Security Dealer Features

* Automatic System Load Shed
– During extended AC power fail, the system battery will be disconnected to prevent irreversible battery failure. Reduces service calls to replace batteries. Dynamic Signaling
*
– Reduces redundant reporting to the central station when multiple reporting methods are used; i.e. digital dialer and AlarmNet radio

Valuable End-User Features

* Viewable on system keypads:
– Exit countdown
– Time and date display*
– Event log* Auto keypad backlighting on entry
** Keyswitch arming
* Programmable macro buttons and single-button arming
* Supports a variety of wireless remote controls for single-button operation
* User Scheduling
– Automatically activates X-10 and relays at programmed times
– Latchkey reports to pagers
– Auto arm/disarm
– “User access” time windows Supports up to four end-user numeric pagers
* * VIP Module allows system control from any touchtone phone
* Chime by zone
* Requires custom alpha keypad

 